[Free] 2017(Nov) Dumps4cert Testinsides CompTIA ISS-003 Dumps with VCE and PDF Download 101-110

Dumps4cert 2017 Nov CompTIA Official New Released ISS-003
100% Free Download! 100% Pass Guaranteed!
http://www.Dumps4cert.com/ISS-003.html

Intel庐 Server Specialist Certification Exam

Question No: 101

Your customer is looking for new servers. Space is very limited; they have room for one new rack and want to add at least 30 servers. The servers need to be able to support E5- 2600 v3 14 core processors, 768GB memory and 8 HDDs. Which of the following configurations would you recommend?

  1. HNS2600TP amp; H2216XXKR2.

  2. R2208WT2YS.

  3. R1208WTXXX.

  4. R1304WTXXX.

Answer: C

Question No: 102

After running the system firmware update package on the Intel庐 Server System R1304WTTGS a message “BMC is in FW transfer mode” appears. Which of the following options describes the reason for this message?

  1. The BMC has not updated because the BMC force update jumper is selected.

  2. Update cannot be finished because of a bad firmware file.

  3. The BIOS needs to be updated to the latest version to match the firmware.

  4. Update is completed, but the BMC force update jumper is enabled.

Answer: D

Question No: 103

A customer has a dual socket server board; and they arecomplaining to your customer that they are constantly getting uncorrectable memory errors. You are asked to resolve the issue for their customer as quickly as possible, as another 10 systems are on order. You have advised that they should swap the “issue”DIMM out of its slot and insert it in the slot of another good DIMM. (Select ALL that apply).

  1. The error moves with the DIMM / Replace the DIMM

  2. The error moves with the DIMM / Replace the server board

  3. The error stays in the same DIMM slot / Replacethe server board

  4. The error stays in the same DIMM slot / Do a memory stress test

  5. The error goes away / Do a memory stress test

  6. The error goes away / Replace the DIMM

  7. The error moves with the DIMM / Do a memory stress test

  8. The error goes away / Replace the server board

  9. The error stays in the same DIMM slot / Replace the DIMM

Answer: A,C,E

Question No: 104

Your customer is asking about reliability in server operation and inparticular asks you how performance might be affected if the memory in BIOS setup is set to Mirroring mode on a server system using an Intel S2600CW board. How would you answer this question? (Select ALL that apply).

  1. The number of channels is halved

  2. Memory speed is doubled

  3. Usable memory is halved

  4. Memory speed is halved

  5. Performance will not be affected

Answer: A,C

Question No: 105

When creating virtual machines your customer asks how to set up each virtual machine and in particular whether there is any feature that provides direct access for PCIe devices to the virtual machines. How would you answer this question?

  1. AES-NI

  2. GVRP

  3. VMDQ

  4. SR-IOV

  5. IQAA

Answer: D

Question No: 106

As the Intel庐 Server Specialist you have an urgent customer call (their customer is still on the phone to them!) complaining that the new server installation is “not working properly!” The Intel庐 RAID controller RS25PB080 is installed in the Intel庐 Server System R2208WT2YS. As you complete your troubleshooting “discovery” with your customer, you find that the Intel庐 RAID Controller is installed in Riser slot 2 and that the controlleris not

visible either in BIOS or in the OS. How should you advise your customer to proceed?

  1. Ensure that a second CPU is installed

  2. Ensure that the additional six pin power connector is correctly installed

  3. This is a PCIe gen3 device and must be configured accordingly

  4. The RAID activation key should be installed

  5. The RAID device should be enabled in BIOS

  6. Upgrade to the latest BIOS

Answer: A

Question No: 107

A customer is not able to enter the RAID BIOS setup utility for an onboard controller. Which of the following troubleshooting steps should an Intel庐 Server Specialist take when trying to resolve the customer’s issue?

  1. Disable quiet boot.

  2. Check whether the RAID 5 activation key is installed.

  3. Make sure the customer is only using SATA drives.

  4. Update the system BIOS to the latest version.

  5. Check themass storage controller mode in BIOS setup.

  6. Verify the HSBPA cable is connected.

  7. Verify the SGPIO cable is connected.

  8. Verify there are disks connected to the motherboard.

  9. B, E, H

  10. A, E, H

  11. C, D, E

  12. A, E, F

Answer: B

Question No: 108

Which of the following are features of Intel庐 VT-d technology (Intel庐 VT Technologyfor directed I/O)? (Select ALL that apply).

  1. Improves system reliability by containing and reporting errant DMA to software (i.e. OS or VMM)

  2. Is a requirement for the use of Microsoft Hyper-V

  3. Is a requirement for the use of VMWare ESX 4

  4. Enablesthe use of Virtual NICs and Switches inside a Hypervisor

  5. Improves I/O performance through direct assignment of a device to a VM

Answer: A,E

Question No: 109

A customer has just completed the integration of a new server system based on an Intel庐 server board. When the customer attempts to power-up the system, it does not boot and instead gives several sequences of beeps. Which of the following documents will help an Intel庐 Server Specialist determine what the beep codes are and where they come from, in order to troubleshoot the issue for the customer?

  1. The product brief for the relevant server board and chassis combination

  2. The Configuration Guide for the relevant server board and chassis combination

  3. QuickStart User guide

  4. The Technical Product Specification document

Answer: D

Question No: 110

Your customer reports that since changing the memory speed settings in Bios Setup on an Intel庐 Server Board S2600CW2 in chassis P4304XXMFEN2 now will not start and 3 beeps can be heard. How would you advise your customer to proceed?

  1. Clear CMOS by jumper

  2. Update the firmware with BIOS recovery jumper enabled

  3. Reset the BMC via jumper

  4. Start the system with one DIMM installed

  5. Remove A/C power from the server for 2 minutes thenswitch on

Answer: A

100% Free Download!
Download Free Demo:ISS-003 Demo PDF
100% Pass Guaranteed!
Download 2017 Dumps4cert ISS-003 Full Exam PDF and VCE

Dumps4cert ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 Dumps4cert IT Certification PDF and VCE

Leave a Reply

Your email address will not be published. Required fields are marked *