[Free] 2017(Nov) Dumps4cert Testinsides CompTIA ISS-001 Dumps with VCE and PDF Download 141-150

Dumps4cert 2017 Nov CompTIA Official New Released ISS-001
100% Free Download! 100% Pass Guaranteed!
http://www.Dumps4cert.com/ISS-001.html

Intel庐 Server Specialist Certification Exam

Question No: 141

An IT administrator wants to back up an entire Intel庐 Modular Server Configuration. Which of the following features does the administrator need for this?

  1. Intel庐 Storage Management Pack

  2. Intel庐 Shared LUN

  3. Intel庐 Advanced Management Pack

  4. Intel庐 Modular Server mini-DIMM

Answer: C

Question No: 142

In what way does the MFSYS25V2 differ from the MFSYS25?

  1. It can support larger capacity hard drives.

  2. It has a new midplane and management module (CMM).

  3. It has higher capacity power supplies.

  4. The chassis colour is changed to black.

Answer: B

Question No: 143

The Intel庐 Modular Server Control (GUI) shows that one hard drive is in a stale condition. Which of the following can trigger this condition? (Select TWO).

  1. The drive being forced offline by the user.

  2. The storage controller module firmware has just been updated.

  3. A disk error.

  4. The hard drive was not mapped to a compute module.

  5. There is insufficient power to run all the drives in this system.

Answer: A,C

Question No: 144

The Intel庐 Modular Server Control dashboard shows one of the compute modules with a “component unfit” error. Which of the following could be the cause of this? (Select TWO).

  1. The server OS has crashed.

  2. The hardware has failed.

  3. The server has lost access to its boot LUN.

  4. There is a failure on the Ethernet switch module.

  5. The CMM has lost communication with this particular server.

Answer: B,E

Question No: 145

Which of the following would lead to a chassis mis-configuration fault on the Intel庐 Modular Server? (Select TWO).

  1. Removal of ESM1 in a chassis with only one Ethernet switch.

  2. Removal of the Chassis Management Module (CMM).

  3. Removal of ESM1 in a chassis with two Ethernet switches.

  4. Insufficient power supplies for a fully populated chassis.

Answer: A,D

Question No: 146

Can a SATA SSD drive and SAS drive be combined in an Intel庐 Modular Server?

  1. Yes, the system supports both drives types without any pre-requisites.

  2. No, you can never mix SATA and SAS drives in an Intel庐 Modular Server system.

  3. Yes, as long as the system has the correct firmware and the SATA converter, and storage pools are based on the same drive type.

  4. Yes, as long as the system is on firmware level 5.0 and the SATA converter AXXTM3SATA is installed in the drive caddy.

Answer: C

Question No: 147

A customer calls and would like to set up link aggregation on two switch modules in an Intel庐 Modular server chassis. What, from the following list, should the customer be informed of? (Select TWO).

  1. Link Aggregation is not supported on the internal ports of the AXXSW1GB Gigabit Ethernet switch module.

  2. Link Aggregation is only supported on the external ports of the AXXSW1GB Gigabit Ethernet switch.

  3. When aggregating internal ports it must be across two switches.

  4. In order to support Link Aggregation between two switches the customer must install mezzanine cards on all compute modules.

  5. Link Aggregation requires the optional Advanced Ethernet Feature pack to support this.

Answer: A,B

Question No: 148

Which of the following is the BEST method to use when troubleshooting an Intel庐 Modular Server Chassis Management Module boot issue?

  1. Attach a serial cable to the CMM serial port, load a console program, and observe where the boot process fails.

  2. Replace the CMM.

  3. Attach a coax cable to the CMM serial port, run system diagnostics through the command line utility, and reinstall the operating system.

  4. Connect remotely and check the logs in the GUI for CMM problems to determine if this is a hardware issue or not.

Answer: A

Question No: 149

Where can the system administrator check to see if a background task is running on the Intel庐 Modular Server? (Select TWO).

  1. By connecting to the storage controller through the serial interface.

  2. In the Intel庐 Modular Server Control GUI, by clicking on the storage controller and the background tasks tab.

  3. By pulling the logfilE.”diagout.user.zip” and checking the storage controller component.

  4. Review the system logs.

  5. In the Intel庐 Modular Server Control GUI, by clicking on the compute module and the background tasks tab.

Answer: B,C

Question No: 150

A customer needs a storage configuration with the highest performance and maximum reliability/redundancy features, but who also has strict budget limitations. Which of the following RAID solutions should an Intel庐 Server Specialist recommend to meet these requirements?

  1. Intel庐 Raid Controller RS2WC080

  2. Intel庐 Raid Controller SRCSASJV

  3. Intel庐 Raid Controller RS2BL040

  4. Intel庐 Raid Activation Key AXXRAKSW5

  5. Intel庐 Raid Activation Key AXXRAKSAS2

Answer: C

100% Free Download!
Download Free Demo:ISS-001 Demo PDF
100% Pass Guaranteed!
Download 2017 Dumps4cert ISS-001 Full Exam PDF and VCE

Dumps4cert ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 Dumps4cert IT Certification PDF and VCE

Leave a Reply

Your email address will not be published. Required fields are marked *